SupportPartner portalLog in to bisly.cloud

Home / Commercial / Solutions / Scalable building automation

A complete building automation system, configured, not programmed

BMS, controllers, room devices, lighting, metering and integrations from one supplier.

Bisly delivers the whole building automation and control system (BACS): the cloud BMS, the on-site Bisly Server, a Bisly Controller 8 on every floor, room controllers, DALI-2 lighting, metering, access and the integrations to the plant already in the building. It is designed to EN ISO 52120-1, class B as standard and class A where you need it, and covers the EPBD monitoring duty from day one. In a conventional project labour is 50-75% of the cost; with Bisly every function is a configuration choice in a digital twin, so the cost of acquisition is 30-40% lower and the same system fits a single plant room or a campus.

Everything a BACS has to do, in one system

EN ISO 52120-1 grades a building's automation function by function. These are the functions Bisly delivers, each with the devices that do the work and the BMS screen that runs it.

Heating and cooling plant

Substations, boilers, heat pumps, chillers and mixing circuits on live schematics: setpoints, heating curves, pump and valve states. Existing plant controllers are supervised over Modbus; where none exist, the Bisly Mini Server and Bisly I/O modules run the loops.

Ventilation and air handling

AHUs from 20+ manufacturers, and any other AHU through a standard Modbus integration. VAV dampers and exhaust fans, with demand-based control from room CO₂ and humidity, weekly schedules and heat-recovery supervision.

Room control

Every room holds its own temperature and air with the Bisly Room Controller 4: radiators, floor heating, fan-coils and split / VRF units through the Bisly AC Gateway 1, window contacts, presence and key cards.

Lighting and shading

DALI-2 lighting per floor through the Bisly DALI Bridge 2, presence and daylight sensors, existing wall switches as DALI-2 inputs, and blinds that follow sun, glare and occupancy.

Metering and energy

Electricity, heat, water and gas read remotely over wired and wireless M-Bus, per building, tenancy and meter, with billing-ready exports and spike alarms.

Access and security

Card readers, locks, intercoms, IP cameras and lifts in the same BMS: credentials per tenant, time rules and a searchable event log.

Monitoring, alarms and trends

Continuous monitoring, logging and benchmarking as the EPBD asks: alarm rules with priorities and delays, every datapoint trended for 5 years, and Adam, the AI assistant, flagging faults in plain language.

The network and the cloud

An isolated automation network behind a pre-configured Bisly router, the Bisly Server on site and bisly.cloud for every building on one login. Control keeps running locally through an internet outage.

One platform, one responsible provider

No stack of software and hardware suppliers to coordinate, and one party answerable for the result.

30-40% lower total cost of acquisition

Optimised devices and a configured deployment: automation work-hours roughly halve, from 1,100 h to 590 h on a typical project.

ROI in under 3 years

It already pays for itself, and now regulation requires it too (EPBD; in Germany, GModG § 56).

Sized to the project, from a single substation to a campus

The same system does the small job and the large one. A single substation, a 2,000 m² office, a 20,000 m² building or a multi-building campus use the same digital twin, the same BMS and the same devices, so a plant room started today joins the building and the portfolio later without a migration, and the price follows the size of the project rather than engineering hours.

one plant room
Small

The Bisly Mini Server (CX01) runs a heating substation, an AHU plant room or an outbuilding on its own: DDC loops on Bisly I/O where no factory controller exists, existing controllers supervised over Modbus. Typical start for a school boiler house or a retrofit that begins in the basement.

Learn more
one building
Medium

The Bisly Server (CX00) supervises the site; a Bisly Controller 8 (CU08) panel per floor runs heating manifolds, fan-coil zones, lighting groups and door locks; the Bisly Room Controller 4 (RC04) decides in every room. The reference design: an 8,000 m² office on 4 floors, one panel per floor, around 1,900 datapoints.

Learn more
a campus or portfolio
Large

bisly.cloud shows every building on one login, compares energy, indoor air and alarms per m² across sites, and reuses the configuration template from the first building on the next. Updates arrive over the uplink, with no site visit.

Learn more

Why it repeats

Configured in a digital twin

Every function is a configuration choice in the digital twin. No controller code is written per project, and nothing is engineered twice.

Pre-configured before installation

Your certified partner configures the controllers in the Bisly platform from the twin while the building goes up, so nothing is programmed on site in the final weeks.

Scan-to-connect

Electricians install with the Installer App: room first, device second, no laptop at the panel. Every device reports in before the installer leaves the room.

One cloud BMS, any browser

Floor plans, plant schematics, alarms, schedules, metering and trends at bisly.cloud for one building or all of them, with Adam, the AI assistant, watching every datapoint.

Open protocols

Modbus RTU / TCP, M-Bus wired and wireless, DALI-2, KNX via a KNX/IP gateway, Matter / Thread, OSDP, SIP, ONVIF, documented REST API. Bisly supervises the plant's existing controllers.

Compliant from day one

EN ISO 52120-1 class B as standard, class A where you need it; EPBD monitoring, EED remote-readable metering, GModG § 56 in Germany.

From quote to live building, one dataset

  1. Digital twin

    The Sales Configurator builds a twin of the building: site, floors, rooms and the features each room needs. Quote, bill of materials, wiring, panel configuration and control logic are generated from it. No programming.

  2. Pre-configured in the platform

    Your certified partner configures the controllers with Bisly's deployment tools while the building goes up, before it is ready for the automation installation.

  3. Scan-to-connect on site

    Electricians install with the Installer App; the QR code places each device in the twin; the documentation writes itself.

  4. Operate from one BMS

    bisly.cloud runs the building. The twin stays live as the single source of truth for every device, and the next building reuses the template.

The traditional way and the Bisly way

Traditional wayBisly way
EngineeringEngineered per project, with controller code written for each siteEvery function is a configuration choice in the digital twin; nothing is engineered twice
TimingProgramming and testing squeezed into the final months before handoverPre-configured in the platform by the partner while the building goes up, before the automation installation starts
On siteControllers programmed and addressed on site, after every other tradeScan-to-connect: room first, device second, no laptop at the panel
TestingTroubleshooting and rework at the end, when every trade is finishingEvery device reports in before the installer leaves the room; Adam runs the acceptance test
HandoverDelays cascade, overtime rises, quality suffersAutomated documentation, no peak at the end, handover comes sooner
Automation work-hours roughly halve: 1,100 h the traditional way, 590 h the Bisly way, on a typical project. Total cost of acquisition 30-40% lower.

One system, three ways to work with it

Web BMS

bisly.cloud in any browser: the facility manager's floor plans, schematics, alarms, schedules and reports, with Adam answering questions in plain language.

Bisly app

Alarms, room overrides and status on the phone for the maintenance team.

Open interfaces

Modbus for plant integration; documented REST API for PMS, housing and energy platforms, dynamic tariffs (Nord Pool day-ahead prices) and VPP services.

30-40%

lower total cost of acquisition

590 h

automation work-hours on a typical project, down from 1,100 h (indicative)

Under 3 years

return on investment

No. 1

building automation provider in the Baltics

Related

Room automation

Every room and zone under control, in commercial and residential buildings.

Learn more

Energy monitoring

Know where every kWh goes.

Learn more

Remote access and site networking

Run and support the building from anywhere.

Learn more

Send us the drawings. Get a fixed price in 5 working days.

Bring drawings or a room schedule to a 30-minute call. You leave with a points list, a budget from the digital twin and a date for the fixed price.

A 30-minute discovery call. Scope and a fixed price within 5 working days.